Type SHD-GC, Type MP, Type W EPR/CPE/TPU Mining Cable
Suitable for mining and building machinery, conveyors, shifts, and cranes.
HUADONG CABLE GROUP
Type SHD-GC CPE/TPU Mining Cable
![](https://www.huadongcables.com/wp-content/uploads/2023/05/Type-SHD-GC-3C-5kv-CPE.jpg)
Voltage: 2kV, 5kV, 8kV, 15kV, 25kV
Type: Flat or Round
Conductor: Flexible tinned copper
Insulation: EPR (90°C)
Insulation Shielding: Tinned copper and color-coded nylon braid
Ground Check Conductor: Flexible tinned copper with yellow XLPE insulation
Ground Wires: Flexible tinned copper
Jacket: CPE or TPU
Standard: IEC, BS, DIN, VDE, ASTM, CSA or Customized
Type SHD-PCG CPE/TPU Mining Cable
![](https://www.huadongcables.com/wp-content/uploads/2023/05/19.jpg)
Voltage: 2kV, 5kV
Core: 3 Core
Conductor: Flexible tinned copper
Insulation: EPR (90°C)
Insulation Shielding: Tinned copper and color coded nylon braid
Ground Conductor: Flexible tinned copper located in the center of the cable
Control Ground Conductor: Tinned Copper Conductor/EPR Insulation
Jacket: CPE (Blue, Green, Yellow, Orange, Red, Black)
Type SHD-CGC CPE/TPU Mining Cable
![](https://www.huadongcables.com/wp-content/uploads/2023/05/02.jpg)
Voltage: 2kV, 5kV
Core: 3 Core
Conductor: Flexible tinned copper
Insulation: EPR (90°C)
Insulation Shielding: Tinned copper and color coded nylon braid
Ground Wires: Flexible tinned copper
Control Check Conductor: Tinned copper with yellow insulation located in the central of the cable
Separator Tape: Non-conducting
Jacket: CPE (Blue, Green, Yellow, Orange, Red, Black)
Type W Flat EPR Mining Cable
![](https://www.huadongcables.com/wp-content/uploads/2023/05/09.jpg)
Voltage: 600/2000V
Type: Round or Flat
Core: 2 Core, 3 Core, 4 Core
Conductor: Flexible tinned copper
Insulation: EPR (90°C)
Reinforcement: Synthetic yarn over assembly
Jacket: Mold-cured thermoset
Jacket Color: Black
Standard: IEC, BS, DIN, VDE, ASTM, CSA or Customized
Type G Flat CPE Mining Cable
![](https://www.huadongcables.com/wp-content/uploads/2023/05/Type-G-2C-Flat.jpg)
Voltage: 2kV, 5kV
Core: 3 Core
Conductor: Flexible tinned copper
Insulation: EPR (90°C)
Insulation Shielding: Tinned copper and color-coded nylon braid
Ground Conductor: Flexible tinned copper located in the center of cable
Control Ground Conductor: Tinned Copper Conductor/EPR Insulation
Jacket: CPE (Blue, Green, Yellow, Orange, Red, Black)
Type G-GC CPE/TPU Mining Cable
![](https://www.huadongcables.com/wp-content/uploads/2023/05/15.jpg)
Voltage: 2000V
Type: Flat or Round
Core: 3 Core
Conductor: Flexible tinned copper
Insulation: EPR (90°C)
Ground Wire: flexible tinned copper
Tape: Non-conducting
Jacket: CPE
Jacket Color: Black,blue, green, orange, red, yellow
Standard: IEC, BS, DIN, VDE, ASTM, CSA or Customizede
Type VFD EPR/CPE Mining Cable
![](https://www.huadongcables.com/wp-content/uploads/2023/05/Type-VFD-3-core.jpg)
Voltage: 2000V
Core: 3C conductor + 3C ground wire
Conductor: Tinned copper
Ground Conductor: flexible tinned copper
Power Conductor: Extra flexible tinned rope stranded
Ground Check Wire Optional: Flexible tinned copper with yellow insulation.
Insulation: EPR (90°C)
Shield: Overall tinned copper braid plus aluminum/polyester tape providing 100% coverage
Jacket: CPE (Black)
Type MP EP/CPE Mining Cable
![](https://www.huadongcables.com/wp-content/uploads/2023/05/25.jpg)
Voltage: 5/15kV
Conductor: Copper
Core: 3Core
Strand Shield: Semi-conducting layer
Insulation: EPR
Insulation Shield: Semi-conducting layer under copper tape
Ground Wires: Tinned copper
Ground Check Conductor: 8 AWG 7-wire copper with yellow polypropylene insulation
Jacket: CPE
Type MP-GC XLPE ERP Mining Cable
![](https://www.huadongcables.com/wp-content/uploads/2023/05/Type-MP-GC-3C-XLPE-Insulation-PVC-Sheath.jpg)
Voltage: 25/35kV
Conductor: Copper
Core: 3Core
Strand Shield: Semi-conducting layer
Insulation: XLPE, EPR
Insulation Shield: Semi-conducting layer under copper tape
Ground Wires: Tinned copper
Ground Check Conductor: 8 AWG 7-wire copper with yellow polypropylene insulation
Jacket: PVC
Power Conductors | Grounding Conductors | Nominal Outside Dimensions in. | Approx. Weight lbs. per 1,000 ft. | Ampacity 30°C Ambient Temp | Maximum Tensile Load (lbs.) | ||
Size AWG | Power Conductor Diameter (in.) |
Size AWG | Ground Conductor Diameter (in.) |
||||
2 | 0.321 | 6 | 0.204 | 2.42 | 3500 | 180 | 466 |
1 | 0.366 | 5 | 0.238 | 2.52 | 4080 | 205 | 587 |
1/0 | 0.413 | 4 | 0.259 | 2.64 | 4610 | 236 | 741 |
2/0 | 0.468 | 3 | 0.291 | 2.73 | 4890 | 270 | 934 |
3/0 | 0.518 | 2 | 0.321 | 2.9 | 5589 | 311 | 1178 |
4/0 | 0.584 | 1 | 0.366 | 3.05 | 6820 | 357 | 1178 |
Power Conductors | Grounding Conductors | Nominal Outside Dimensions in. | Approx. Weight lbs. per 1,000 ft. | Ampacity * 40°C Ambient Temp |
|||
Size AWG | No. of Wires per Conductor | Insulation Thickness mils | Size AWG | No. of Wires per Conductor | |||
8 | 133 | 60 | 10 | 49 | 0.97 | 600 | 59 |
6 | 259 | 60 | 10 | 49 | 1.05 | 750 | 79 |
4 | 259 | 60 | 8 | 133 | 1.19 | 1070 | 104 |
2 | 259 | 60 | 7 | 133 | 1.34 | 1480 | 138 |
1 | 259 | 80 | 6 | 133 | 1.51 | 1890 | 161 |
1/0 | 266 | 80 | 5 | 133 | 1.65 | 2340 | 186 |
2/0 | 323 | 80 | 4 | 259 | 1.75 | 2750 | 215 |
3/0 | 418 | 80 | 2 | 259 | 1.89 | 3377 | 249 |
4/0 | 532 | 80 | 2 | 259 | 2.04 | 3980 | 287 |
250 | 627 | 95 | 2 | 259 | 2.39 | 5000 | 320 |
350 | 888 | 95 | 1/0 | 266 | 2.68 | 6750 | 394 |
500 | 1221 | 95 | 2/0 | 323 | 3.03 | 8900 | 487 |
Power Conductors | Nominal Outside Diameter in. | Approx. Weight lbs. per 1,000 ft. | Ampacity 90°C Conductor 30°C Ambient Temp |
|
Size AWG | Insulation Thickness mils | |||
8 | 60 | 0.99 | 670 | 59 |
6 | 60 | 1.1 | 890 | 79 |
4 | 60 | 1.27 | 1250 | 102 |
2 | 60 | 1.48 | 1800 | 134 |
1 | 80 | 1.68 | 2270 | 157 |
1/0 | 80 | 1.79 | 2680 | 181 |
2/0 | 80 | 1.93 | 3200 | 211 |
3/0 | 80 | 2.07 | 3627 | 243 |
4/0 | 80 | 2.26 | 4650 | 280 |
Size AWG | Power Conductors | Grounding Conductors | Jacket Thickness mm | Ground Check Conductor Size AWG2 | Nominal Outside Dimensions mm | Approx. Weight kg’s per km | ||
Minimum No. of Wires per Conductor | Insulation Thickness mm | Size AWG | Minimum No. of Wires per Conductor | |||||
1/0 | 18 | 8.76 | 4 | 7 | 4.3 | 8 | 73.4 | 7452 |
2/0 | 18 | 8.76 | 3 | 7 | 4.3 | 8 | 76.3 | 8256 |
3/0 | 18 | 8.76 | 2 | 7 | 4.3 | 8 | 78.9 | 9223 |
4/0 | 18 | 8.76 | 1 | 19 | 4.3 | 8 | 81.9 | 10312 |
250 | 35 | 8.76 | 1/0 | 19 | 4.3 | 8 | 84.7 | 11289 |
350 | 35 | 8.76 | 2/0 | 19 | 5.1 | 8 | 91.8 | 14173 |
500 | 35 | 8.76 | 3/0 | 19 | 5.1 | 8 | 98.9 | 17818 |
![](https://www.huadongcables.com/wp-content/uploads/2023/06/1-min.jpg)
Trailing System Operation
![](https://www.huadongcables.com/wp-content/uploads/2023/06/2-min.jpg)
Shearer Operating System
![](https://www.huadongcables.com/wp-content/uploads/2023/06/3-min.jpg)
Mining Tunnel System
![](https://www.huadongcables.com/wp-content/uploads/2023/06/4.jpg)
Underground Mining Cable Install