2~30C CUR, CAR, RE- 2PNCT/3PNCT Felexible Cable for Reeling/Festoon/Carrier Drum System

CUR-2PNCT/CUR-2PNCT-SB (Festoon)


Voltage:
600V
Test Voltage: 3000V /1 minute
Conductor: Copper /Tinned annealed copper
Insulation: EPR compound
Shield braid: Copper wire/Tinned Copper wire
Outer sheath: Chloroprene rubber
Rated Temperature: 80 degrees C
Feature: High flexibility
Application: Festoon System and Lift System

CUR-3PNCT/CUR-3PNCT-SB (Festoon)

Voltage: 600V
Test Voltage: 3000V /1 minute
Conductor: Copper /Tinned annealed copper
Insulation: EPR compound
Shield braid: Copper wire/Tinned Copper wire
Outer sheath: Chloroprene rubber
Reinforcement: Embedded yarn braid
Rated Temperature: 80 degrees C
Feature: High flexibility and impact resistance
Application: Festoon System and Lift System

Flat Type SK-2PNCT for Festoon System

Voltage: 600V
Test Voltage: 3000V /1 minute
Conductor: Copper /Tinned annealed copper
Insulation: EPR compound
Shield braid: Copper wire/Tinned Copper wire
Outer sheath: Chloroprene rubber
Reinforcement: Embedded yarn braid
Rated Temperature: 80 degrees C
Feature: High flexibility
Application: Festoon System and Lift System

No. of Cores Conductor Insulation Thickness (mm) Sheath Thickness (mm) Approx. Overall Diameter (mm) Approx. Mass (kg/km)
Size (mm2) Construction (No./mm) Outer Diameter (mm)
12 0.75 30/0.18 1.1 0.8 2.1 17 335
1.25 50/0.18 1.5 0.8 2.2 18.5 440
2 37/0.26 1.8 0.8 2.3 20 560
3.5 45/0.32 2.5 0.8 2.5 24 845
16 0.75 30/0.18 1.1 0.8 2.2 18.5 415
1.25 50/0.18 1.5 0.8 2.3 21 550
2 37/0.26 1.8 0.8 2.4 22 705
3.5 45/0.32 2.5 0.8 2.7 26 1080
20 1.25 50/0.18 1.5 0.8 2.5 23 680
2 37/0.26 1.8 0.8 2.6 25 870
24 1.25 50/0.18 1.5 0.8 2.6 25 810
2 37/0.26 1.8 0.8 2.7 27 1050
3.5 45/0.32 2.5 0.8 3 32 1610

RE-2PNCT/RE-3PNCT for Reeling System

Voltage: 600V
Test Voltage: 3000V /1 minute
Conductor: Copper /Tinned annealed copper
Insulation: EPR compound
Shield braid: Copper wire/Tinned Copper wire
Reinforcement: Embedded yarn braid
Outer sheath: Chloroprene rubber
Core identification: Color coding/tracer method
Feature: High resistance to lateral pressure and bending
Application: Suitable for the reel systems (manually wound) for crane travel

RE(V)-2PNCT-FR for Vertical Reeling


Voltage:
600V
Test Voltage: 3000V /1 minute
Conductor: Copper /Tinned annealed copper
Insulation: EPR compound
Shield braid: Copper wire/Tinned Copper wire
Reinforcement: Embedded yarn braid
Outer sheath: Chloroprene rubber
Core identification: Color coding/tracer method
Feature: High resistance to lateral pressure and bending
Application:Vertical reel system used in landfills, etc.

Flat 2PNCT/3PNCT (Reeling System)

Voltage: 600V
Conductor: Copper /Tinned annealed copper
Insulation: EPR compound
Shield braid: Copper wire/Tinned Copper wire
Outer sheath: Chloroprene rubber
Core identification:  For power or control core unit
3-core (black, white, and red)
4-core (black, white, red, and green)
Control cores
Feature: High resistance to lateral pressure and bending
Application:Reel system (Traveling).

No. of Cores Conductor Insulation Thickness (mm) Thickness of Reinforcement (mm) Sheath Thickness (mm) Approx. Overall Diameter (mm) Approx. Mass (kg/km)
Size (mm2) Construction (No./mm) Outer Diameter (mm)
3 14 88/0.45TA 4.9 1.2 1 3.3 26 940
22 7/20/0.45TA 7 1.6 1 3.7 32 1490
30 7/27/0.45TA 8.1 1.6 1 3.9 35 1830
4 38 7/34/0.45TA 9.1 1.6 1 4.2 40 2720
6 3.5 3/0.32TST+45/0.32TA 2.6 1.2 0.5 3.2 24 730
8 3/0.32TST+50/0.45TA 3.8 1.2 0.5 3.5 28 1180
10 3.5 3/0.32TST+45/0.32TA 2.6 1.2 1 3.7 32 1190
12 3.5 3/0.32TST+45/0.32TA 2.6 1.2 1 3.7 33 1320
16 3.5 3/0.32TST+45/0.32TA 2.6 1.2 1 3.9 36 1650
20 3.5 3/0.32TST+45/0.32TA 2.6 1.2 1 4.1 40 2000
24 3.5 3/0.32TST+45/0.32TA 2.6 1.2 1 4.4 44 2400
30 3.5 3/0.32TST+45/0.32TA 2.6 1.2 1 4.5 46 2830

CAR-2PNCT/CAR-3PNCT (Carrier Drum)

Voltage: 600V
Test Voltage: 3000V /1 minute
Conductor: Copper /Tinned annealed copper
Insulation: EPR compound
Shield braid: Copper wire/Tinned Copper wire
Reinforcement: Embedded yarn braid
Outer sheath: Chloroprene rubber
Core identification: Color coding/tracer method
Feature: Lateral pressure resistance
Application: Traversing carrier roller system of overhead cranes and cable chain system.

TOR-2PNCT Cable (Torsion System)


Voltage:
600V
Test Voltage: 3000V /1 minute
Conductor: Copper /Tinned annealed copper
Insulation: EPR compound
Shield braid: Copper wire/Tinned Copper wire
Outer sheath: Chloroprene rubber
Core identification: Color coding/tracer method
Feature: High torsion resistance
Application: Suitable to the revolving parts of rotary cranes.
Standards:
JIS C 3327 or other international standards

SPD-FHNCT for Spreader Basket

Voltage: 600V
Test Voltage: 3000V /1 minute
Conductor: Copper /Tinned annealed copper
Insulation: ETFE insulation
Outer sheath: Chloroprene rubber
Core identification: Color coding/tracer method
Feature: Stable collecting performance into the basket, and high lateral pressure resistance
Application: Suitable for gravity collector basket system of the container crane at harbors (for Quayside cranes)..
Standards:
JIS or other international standards

No. of Cores Conductor Insulation Thickness (mm) Sheath Thickness (mm) Approx. Overall Diameter (mm) Approx. Mass (kg/km)
Size (mm2) Construction (No./mm) Outer Diameter (mm)
3 8 50/0.45 3.7 1 2.1 17 475
14 88/0.45 4.9 1 2.3 20 730
22 7/20/0.45 7 1.2 2.7 26 1180
4 38 7/34/0.45 9.1 1.2 3.2 34 2280
6 3.5 45/0.32 2.5 0.8 2.1 17 465
8 50/0.45 3.7 1 2.4 22 890
10 3.5 45/0.32 2.5 0.8 2.5 23 790
12 3.5 45/0.32 2.5 0.8 2.5 24 815
16 3.5 45/0.32 2.5 0.8 2.7 26 1080
20 3.5 45/0.32 2.5 0.8 2.8 29 1330
24 3.5 45/0.32 2.5 0.8 3 32 1630
30 3.5 45/0.32 2.5 0.8 3.2 36 2080

Crane cable application environment

Reeling Operation System

Festoon Operation System

Basket Operation System

Chain Operation System

Trailing Operation System

    Leave your inquiry requirment, our tem will work together for your project

    get quote by E-mail: sales@huadongcables.com

    * Your Name

    * Your Email

    Your Phone or WhatsApp

    Your Country

    * Your Requirement