Huadong Cable Group is professional Overhead line bare conductor manufacturer, the Aluminum bare conductor including: AAC/ AAAC/ACSR/ACS/GSW and insulation overhead ABC Cable. and can custom the size according to your requirement.
Application:
Used as bare overhead conductor for primary and secondary distribution. Designed for utilizing a high-strength aluminum-alloy to achieve a high strength-to-weight ratio; affords good sag characteristics.
(1)AAAC conductors are extensively used for overhead distribution and transmission lines adjacent to ocean coastlines where there can be a problem of corrosion in the steel of an ACSR construction.
(2)The aluminum alloy conductors are used in replace of single-layer ACSR conductors to reduce power loss in overhead distribution and transmission lines,when replacing the aluminum conductor steel reinforced , the AAAC can save 5-8% of the construction cost.
(3)AAAC referred to have higher strength but lower conductivity than pure aluminum. Being lighter, alloy conductors can sometimes be used to replace the conventional ACSR.
IEC Standard AAAC Condcutor Parameter Date
Code number | Area | Number of wires | Diameter | Linear mass | Rated strength | D.C resistance | |
mm2 | Wire(mm) | Cond(mm) | kg/km | kN | Ohm/km | ||
16 | 18.6 | 7 | 1.84 | 5.52 | 50.8 | 6.04 | 1.7896 |
25 | 29 | 7 | 2.3 | 6.9 | 79.5 | 9.44 | 1.1453 |
40 | 46.5 | 7 | 2.91 | 8.72 | 127.1 | 15.1 | 0.7158 |
63 | 73.2 | 7 | 3.65 | 10.9 | 200.2 | 23.06 | 0.4545 |
100 | 116 | 19 | 2.79 | 14 | 319.3 | 37.76 | 0.2877 |
125 | 145 | 19 | 3.12 | 15.6 | 399.2 | 47.2 | 0.2302 |
160 | 186 | 19 | 3.53 | 17.6 | 511 | 58.56 | 0.1798 |
200 | 232 | 19 | 3.95 | 19.7 | 638.7 | 73.2 | 0.1439 |
250 | 290 | 19 | 4.41 | 22.1 | 798.4 | 91.5 | 0.1151 |
315 | 366 | 37 | 3.55 | 24.8 | 1008.4 | 115.29 | 0.0916 |
400 | 465 | 37 | 4 | 28 | 1280.5 | 146.4 | 0.0721 |
450 | 523 | 37 | 4.24 | 29.7 | 1440.5 | 164.7 | 0.0641 |
500 | 581 | 37 | 4.47 | 31.3 | 1600.6 | 183 | 0.0577 |
560 | 651 | 61 | 3.69 | 33.2 | 1795.3 | 204.96 | 0.0516 |
BS Standard AAAC Condcutor Parameter Date
Code Name | Area | No.of wires | Diameter | Mass per unit length | Rated strength | DC resistance | |
mm2 | Wire(mm) | Cond(mm) | kg/km | kN | Ω/km | ||
BOX | 18.8 | 7 | 1.85 | 5.55 | 51.4 | 5.55 | 1.748 |
ACACLA | 23.8 | 7 | 2.08 | 6.24 | 64.9 | 7.02 | 1.3828 |
ALMOND | 30.1 | 7 | 2.34 | 7.02 | 82.2 | 8.88 | 1.0926 |
CEDAR | 35.5 | 7 | 2.54 | 7.62 | 96.8 | 10.46 | 0.9273 |
DEODAR | 42.2 | 7 | 2.77 | 8.31 | 115.2 | 12.44 | 0.7797 |
FIR | 47.8 | 7 | 2.95 | 8.85 | 130.6 | 14.11 | 0.6875 |
HAZEL | 59.9 | 7 | 3.3 | 9.9 | 163.4 | 17.66 | 0.5494 |
PLNE | 71.6 | 7 | 3.61 | 10.8 | 195.6 | 21.14 | 0.4591 |
HOLLY | 84.1 | 7 | 3.91 | 11.7 | 229.5 | 24.79 | 0.3913 |
WILLOW | 89.7 | 7 | 4.04 | 12.1 | 245 | 26.47 | 0.3665 |
OAK | 118.9 | 7 | 4.65 | 14 | 324.5 | 35.07 | 0.2767 |
MULBERRY | 150.9 | 19 | 3.18 | 15.9 | 414.3 | 44.52 | 0.2192 |
ASH | 180.7 | 19 | 3.48 | 17.4 | 496.1 | 53.31 | 0.183 |
ELM | 211 | 19 | 3.76 | 18.8 | 579.2 | 62.24 | 0.1568 |
POPLAR | 239.4 | 37 | 2.87 | 20.1 | 659.4 | 70.61 | 0.1387 |